Magellan MG-6060 Manual de Instalação Página 14

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 52
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 13
14 Programming Guide
[094] Zone Options Bold = Default setting
Option OFF ON
[1] Stay delay zones Disabled Enabled
[2] Report zone restore On Bell cut-off On zone closure
[3] & [4] Tamper recognition options See table
See table
See table
See table
[5] Generate tamper trouble if detected on bypassed zone No Yes
[6] & [7] Wireless transmitter supervision options See table
See table
See table
See table
[8] Generate supervision trouble if detected on bypassed zone No Yes
[095] Zone Options Bold = Default setting
Option OFF ON
[1] Zone 15 is hardwire zone 1 Disabled Enabled
[2] Zone 16 is hardwire zone 2 Disabled Enabled
[3] EOL (End-Of-Line) resistors No EOL Use EOL resistors
[4] to [8] Future use Future use Future use
[3] [4]
OFF OFF - Disabled
OFF ON - Trouble only
ON OFF - Disarmed: Trouble only
- Armed: Follow zone’s alarm type (page 8)
ON ON - Disarmed: Audible alarm
- Armed: Follow zone’s alarm type (page 8)
[6] [7]
OFF OFF - Disabled
OFF ON - Trouble only
ON OFF - Disarmed: Trouble only
- Armed: Follow zone’s alarm type (page 8)
ON ON - Disarmed: Audible alarm
- Armed: Follow zone’s alarm type (page 8)
Vista de página 13
1 2 ... 9 10 11 12 13 14 15 16 17 18 19 ... 51 52

Comentários a estes Manuais

Sem comentários