Installation Manual
Marine Magellan 6130/6160
Table of Content
Introduction……………………………….....2
Section 1: Installation Consideration...2
Supply Voltage Considerations...........................2
Location Considerations…….…………...............3
Section 2: Mounting………………………..4
Marine Magellan……………………………..........4
Artion GSM Module…………………....................5
Artion Battery Backup...…………………………...5
Section 3: Electrical Installation…………7
AC Installations………………….…………………7
DC Installations……………...………………….....9
Internal Battery Backup / Marine Magellan......9
Communication Lines…………………......9
Section 4: Programming…………………...12
1 Language……………………………………..12
2 - User Profile……………………………………12
3 Communicator………………………………..14
4 Delays and Tones……………………………17
5 System Test…………………………………..17
6 - Zone Profile: Overview…………………....18
Zone Definitions………………………..18
Zone Hardware Descriptions…………20
DCTXP2…………………..…….……...20
PMD-75 Motion Detector……………...22
SD-738 Smoke Detector………………23
Battery Low Voltage Detector………...23
High Water Alarm……………………...25
6 - Zone Profile: Programming…………...……..25
7 Output Profile: Overview…………………….27
PGM Activation Events ……………….27
PGM Electrical Installation……………29
7 Output Profile: Programming……………….29
8 Keypad Profile Overview………………....31
8 - Keypad Profile Programming……….……....33
9 Repeater Profile Overview………...………..33
9 - Repeater Profile Programming……..……….33
10 Signal Strength………………………..........34
11 Passwords…………………………..……....34
Console Trouble…………………………..……...35
AC Diagram……………………………………….37
DC Diagram……………………………………….38
PGM Wiring Examples………………………39 -42
Programming web…………………………......43
Marine Magellan Keypad Description…….......4
id85386625 pdfMachine by Broadgun Software - a great PDF writer! - a great PDF creator! - http://www.pdfmachine.com http://www.broadgun.com
Vista de página 0
1 2 3 4 5 6 ... 43 44

Resumo do Conteúdo

Página 1 - Table of Content

1 Installation Manual Marine Magellan 6130/6160 Table of ContentIntroduction………………………………...2 Section 1: Installation Consideration…...

Página 2

10 Diagram 8 Diagram 9

Página 3

11 Diagram 10 Diagram 11 Diagram 12

Página 4 - Marine Magellan

12 Section 4: Programming With the Marine Magellan and Artion GSM module now powered up and communicating with each other, it is time to program

Página 5 - Artion Battery Backup

13 for a total 16 maximum remotes on the system. In this section you have the ability to change user passwords, user voice labels, and add/delete r

Página 6

14 label is the person who will be using that password. (Examples: captain, first mate, owner, etc.) 6.) To program a remote to that user p

Página 7

15 1.) From the “Voice Report” menu Press “ok”. 2.) From the “Add Tel. # 1” menu Press “ok”. 3.) Enter your first telephone recipient.

Página 8

16 9.) From the “Communicator” menu Press “ok”. Utility Reporting Utility reporting is an option that sends out a pre-recorded message for specifi

Página 9

17 4 – Delays and Tones This menu allows you to set entry / exit times as well as associated sounds for the Marine Magellan. Below are the defini

Página 10 - Diagram 9

18 6 - Zone Profile Description Zones are defined as the assorted wireless sensors that transmit open/close conditions to the Marine Magellan

Página 11

19 Delay zone opens, the console will wait until the Entry Delay Timer of the zone that opened first has elapsed. This feature is commonly used whe

Página 12

2 Introduction Congratulations on your purchase of the Marine Magellan wireless security and monitoring system for your yacht (Diagram 1). The sys

Página 13 - System Master Code

20 Zone Hardware Descriptions This section loosely describes the basic operation of the assorted zones for the system. For more specific data on th

Página 14

21 Diagram 15 Mounting It is suggested that you first apply the door contact and magnet with double sided tape and test it before perman

Página 15

22 Diagram 16 PMD-75 Motion Detector Typical Position: Salon, Stateroom, and Hallway Typical Zone Definition: Follow or Follow / Stay Po

Página 16 - Report Types

23 into position. This will activate the motion detector’s walk-test mode for 3 minutes. Learn Mode Power up the unit and allow the LED to cycle ou

Página 17

24 more than 2 minutes. The Low voltage sensor is mounted in a sealed, waterproof, plastic enclosure. Typically it is hooked up to the primary dom

Página 18

25 Diagram 20 High Water Alarm Typical Position: Bilge Areas Typical Zone Definition: 24 Hour Buzzer Power: 2 x “AAA” Description: The High

Página 19

26 just makes more sense that having the zones randomly placed. 1.) Select Zone Profile by pressing “ok” 2.) Choose which Zone # you wish to ad

Página 20

27 8.) To add another zone to the next available location and repeat the process press “yes”, otherwise press “no”. 7 – Output Profile

Página 21

28 Follow Alarm Description: The PGM will activate for the entire duration while in alarm. The only way to deactivate the PGM is by disarming the

Página 22 - PMD-75 Motion Detector

29 PGM Electrical Installation Before beginning the PGM electrical installation to control a device it is important to understand the power specifi

Página 23

3 Section 1: Installation Consideration The placement of the individual components of the Marine Magellan system is very important. The inst

Página 24 - Electrical Connection

30 3.) If utilizing a “2WPGM” press “yes” and continue to the next step. If utilizing a hardwired “PGM 1” or “PGM 2” (Output 1 and Output 2

Página 25 - 6 - Zone Profile Programming

31 8.) Now you will be prompted to program the PGM to trigger on/off with the remote as a secondary activation event. Select “yes” if you want

Página 26

32 Diagram 21 Diagram 22

Página 27

33 Diagram 23 Keypad Profile Programming 1.) To add a keypad press “ok” 2.) You can have up to four wireless keypads on the Ma

Página 28

34 MG-RPT1 per system. The Wireless Repeater also provides one PGM and one zone input with two-way wireless communication with the panel. The Repea

Página 29 - 7 – Output Profile

35 are put in place to give varying levels of control between the owner and installer. For Example, an installer can add/delete zones from a system

Página 30

36 Table 2

Página 31 - 8 – Keypad Profile

37 Appendage 1 AC Installation

Página 32

38 Appendage 2 DC Installation

Página 33 - 9 – Repeater Profile

39 Appendage 3 Hardwired PGM 1 Relay setup

Página 34

4  There must be an adequate wire run behind the Marine Magellan, Artion, and the Artion Battery Backup Case (if applicable) so wiring is not expo

Página 35

40 Appendage 4 Hardwired PGM 2 Relay Setup

Página 36 - Table 2

41 Appendage 5 2WPGM Wiring setup (switching load below 5 amps)

Página 37 - AC Installation

42 Appendage 6 2WPGM Wiring setup (switching load above 5 amps)

Página 38 - DC Installation

43 Appendage 7 Programming Web

Página 39 - Hardwired PGM 1 Relay setup

44 Appendage 8 Marine Magellan Buttons

Página 40 - Hardwired PGM 2 Relay Setup

5 Diagram 3 3. Place the console back plate flush against the mounted wall plate as shown in Diagram 3. 4. Slide the Marine Magellan’s op

Página 41

6 Diagram 4 Diagram 5

Página 42 - Appendage 6

7 Section 3: Electrical Installation * Power should be denied when making all electrical connections. Only apply power when all wire connections

Página 43 - Programming Web

8 Diagram 6 Diagram 7

Página 44 - Marine Magellan Buttons

9 DC power Setup Marine Magellan The Marine Magellan panel can easily be powered from the vessels 12VDC system. Simply get a constant voltage